1.3.9 Special Systems

1.3.9.1 5/8 Systems

In applications with large particles or materials in the source liquid, a 5/8” ID
system will help prevent clogging. The added diameter adds 66% more volume
to the entire system. As of 2010, both composite and discrete samplers are
available in 5/8”. Smaller pump systems (PVS4120) have minimal capacity
running the larger volume of the 5/8” ID so the larger pump systems
(PVS4100) are recommended.

For a sampler to increase to a 5/8” ID, the following parts and components are
changed to allow for more volume: intake tube, volume control tube, all
fittings, metering chamber, metering chamber lid, discharge tube, sample
container cover, sinker or strainer, and the distributor assembly (for discrete
models).

1.3.9.2 MISA Systems – Teflon and Glass

In applications wherein the water sample must be prevented from coming into
contact with any plastics, a MISA system is recommended. For example, when
testing for acid/base/neutral extractable organics and pesticides, the MISA
system will keep the final sample clean from any contaminants.

MISA stands for “Municipal/Industrial Strategy for Abatement,” and includes
changing all “wetted” components of the sampling system, i.e., everything that
comes in contact with the final sample. The chart below outlines the key
changes made to the sampler for a MISA system.

TABLE 1-13. MISA System Changes

Component Standard

Material

MISA System Material

Intake Tube

PVC

Teflon-Lined PVC

Sinker/Strainer Lead

Sinker

Stainless Steel Sinker/Strainer

Fittings Brass

Stainless

Steel

Metering Chamber

Acrylic

Pyrex

Metering Chamber Cover

Delrin

Teflon with Steel Bracing Ring

Discharge Tube

Latex

Silicone

Sample Container(s)

HDPE (or PP)

Glass

O-Rings

Buna-N (or Viton)