Server.tcpportex, Name, Description – Campbell Scientific LoggerNet Server SDK User Manual
Page 68: Com return values, 2 methods, Server.startserver()

Section 14. CsiServer Control Reference
Server.tcpPortEx
Name
Server.tcpPortEx As Long
Description
This property sets the TCP port that the LoggerNet server will use when
listening for client connections and must be set before starting the LoggerNet
server. LoggerNet uses TCP port 6789 by default This property accepts the
full range of valid TCP port numbers 1 – 65535.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
14.1.2 Methods
Server.startServer()
Name
Server.startServer()
Description
This method starts the limited LoggerNet server (CORALIB3.DLL). The
CORALIB3.DLL must exist in the application folder, the PATH environmental
variable, or the Windows directory or this method will fail.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_ALREADY_STARTED
Error: This error is returned if the
Server control has already started
the LoggerNet server
E_CSI_INVALIDARG
Error: No working directory set
E_CSI_FAIL
Error: Another LoggerNet server
not started by the Server control is
already running or an unexpected
error has occurred
14-4