Appendix A. Server and Device Operational Statistics Tables
Applies To: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T,
CR10X-TD, CR510-TD, CR23X-TD, CR9000, CR5000, CR10X-PB, CR510-
PB, CR23X-TP, CR205, CR210, CR215, CR1000, CR3000, CR800, and
CR850.
Description: The number of values in holes that need to be collected from the
datalogger.
A.2.18 Values in Uncollectable Holes
Column Name: “Values in Uncollectable Holes”
Column Definition Description: “Uncoll Holes”
Type: uint4
Applies To: CR10T, CR0X-TD, CR510-TD, CR23X-TD
Description: The total number of values that have been in uncollectable holes
since the device was started or the statistic was reset.
A.2.19 Line State
Column Name: “Line State”
Column Definition Description: “Line State”
Type: Enumeration
Applies To: All Devices
Description: The current line state for this device. The following values are
defined:
1. Not Applicable – In its current configuration, this device will not
communicate directly with the server. This value will appear in
association with BMP1 dataloggers connected to the server through
an RF95T.
2. Off-Line – The server has no communication resources open for this
device.
3. On-Line – The server has communication resources open for this
device.
4. Transparent – This device has been dialed to reach a child device.
5. Undialing – The child devices have gone off-line and this device is
cleaning up the link so that it can go to an off-line state.
6. Comm-Disabled – Communications are disabled for either this
device, its parent, or for the whole network.
7. Unreachable – This device cannot be reached through the network.
8. Pending – The device has requested the link from its parent but that
request is still pending.
9. Targeted – The device has requested the link from its parent and its
parents are being dialed to open the link.