4. Connect the three cables to the bottom of the electronics box around the

U-bolt on the rain shield (see Figure 3). If there is not enough room for
the connectors around the U-bolt, make sure the electronics box is
mounted at a highest possible position (see step 2).

FIGURE 3. Attaching cables to the electronics box.

5. Place the front cover back on the rain shield and tighten the two pan-head

screws to secure it in place.

6. Gather any loose cables and tie them up, using cable ties, onto the tripod

or tower mast.

4. Wiring

The KH20 sensor is shipped with a power/signal cable with a 25 ft standard
lead length. Table 1 shows the connections for the KH20 to the CR1000,
CR3000, and CR5000.

TABLE 1. Datalogger Connections for Differential Measurement

Function

Wire Color

CR1000/CR3000/CR5000

KH20 Signal +

White

Differential Input (H)

KH20 Signal -

*Black

Differential Input (L)

KH20 Power +

Red

12V

KH20 Power -

Black (from Red/Black set)

G

Shield Clear

*Jumper to

with user supplied wire