beautypg.com

Initial inspection, 1 ships with, Quickstart – Campbell Scientific CS705 Tipping Bucket Snowfall Adapter User Manual

Page 8: Ships with

background image

CS705 Snowfall Adapter

3. Initial Inspection

• Upon receipt of the CS705, inspect the packaging and contents for

damage. File damage claims with the shipping company.

• Immediately check package contents against the shipping documentation

(see Section 3.1, Ships With). Contact Campbell Scientific about any
discrepancies.

3.1 Ships With

The CS705 is shipped with the CM270, CS705 Mounting Kit (pn 20621).
Refer to FIGURE 4-1 for information on positioning the various mounting
hardware.

The CM270 mounting kit includes the following:

• (1) band clamp (pn 20605)

• (1) band clamp (pn 20606)

• (1) storage mount (pn 20636)

• (3) screws (pn 14108, 8-32)

• (1) tipping bucket rain gage mount (pn 20637)

• (1) U-bolt with matching nuts (pn 17492)

• (2) flat washers (pn 4365)

• (2) lock washers (pn 4366)

• (1) U-bolt bracket (pn 20638)

• (1) funnel (pn 14087)

4. Quickstart

Siting considerations and mounting pole options are listed in Section 7,
Installation.

Equipment required:

• Pail

• Hose with a 0.5 inch inner diameter (must be long enough to span the

distance from the funnel to the pail)

• CM300-series mounting pole or user-supplied pole (see Section 7.2,

Mounting Pole)

• TE525WS Texas Electronics Rain Gage

• CS705 Snowfall Adapter

• CM270 Mounting Kit (included with the CS705)

• PGE antifreeze

2