Installation – Campbell Scientific CMP3 Pyranometer User Manual

Page 6

background image

CMP3-L Pyranometer


Temperature Dependence of
sensitivity:

+ 5% (-10º to + 40ºC)

Tilt response (+80º) (at 1000 W/m

2

):

< + 2%

OTHER SPECIFICATIONS

Expected accuracy for daily sums:

+ 10%

Spectral range (50% points, nm):

310 to 2800 nm

Sensitivity:

5 to 20

μV W

-1

m

2

Typical signal output for atmospheric
applications:


0 to 15 mV

Impedance:

30 to 100

Ω

Operating Temperature:

-40º to +80ºC

Max. irradiance:

2000 Wm

-2

Detector:

Copper-constantan multi junction
thermopile

Level accuracy:

1 degree

DIMENSIONS / SHIPPING DIMENSIONS

CMP3-L:

3 in dia x 4 in / 8x12x4 in

WEIGHT/SHIPPING WEIGHT

CMP3-L:

1.2 lbs / 1.8 lbs

3. Installation

The CMP3-L is usually installed horizontally, but can also be installed at any
angle including an inverted position. In all cases it will measure the flux that is
incident on the surface that is parallel to the sensor surface.

Site the CMP3-L to allow easy access for maintenance while ideally avoiding
any obstructions above the plane of the sensing element. It is important to
mount the CMP3-L such that a shadow will not be cast on it at any time.

If this is not possible, try to choose a site where any obstruction over the
azimuth range between earliest sunrise and latest sunset has an elevation not
exceeding 5

°. Diffuse solar radiation is less influenced by obstructions near

the horizon. For instance, an obstruction with an elevation of 5

° over the

whole azimuth range of 360

° decreases the downward diffuse solar radiation

by only 0.8%.

The sensor should be mounted with the cable pointing towards the nearest
magnetic pole, e.g., in the Northern Hemisphere point the cable toward the
North Pole.