Section 2. Station Installation

2-4

FIGURE 2.2-2. TCAV Spatial Averaging Thermocouple Probe

2.3 Wiring

Table 2.3-1 lists the connections to the CR23X for the standard Bowen ratio
sensors measured by the example program. Because the air temperature
measurements are so critical, the air temperature thermocouples are connected
to differential channel 4 (the channel that is closest to the reference
temperature thermistor). The input terminal strip cover for the CR23X must be
installed once all connections have been made and verified (Section 13.4 of
CR23X manual).

TABLE 2.3-1. CR23X/Sensor Connections for Example

Program

CHANNEL SENSOR

COLOR

1H Q7.1

RED

1L Q7.1

BLACK

SHIELD CLEAR

2H HYGROMETER

PRT

GREEN

2L HYGROMETER

PRT

WHITE

HYGROMETER PRT

BLACK

3H TCAV

PURPLE

3L TCAV

RED

TCAV CLEAR

4H

UPPER 0.003 TC - CHROMEL

PURPLE

4L

LOWER 0.003 TC - CHROMEL

PURPLE

40 GAUGE CHROMEL
CONSTANTAN

STAINLESS STEEL
TUBE

HI

(PURPLE)

LO

(RED)

24 GAUGE
CHROMEL
CONSTANTAN