EXAMPLE 3. Sample CR10(X) Program when Long Leads are Required

;{CR10X}
;
*Table 1 Program

01:

10

Execution Interval (seconds)

01:

Pulse (P3)
1:

1

Reps

2:

2*

Pulse Channel 2

3:

22

Switch Closure, Output Hz

4:

1*

Loc [ WndS_m_s ]

5:

0.7990

Mult

6:

0.2811

Offset

;Set the wind speed to zero if the wind is not blowing.
;
02:

If (X<=>F) (P89)
1:

1*

X Loc [ WndS_m_s ]

2:

1

=

3:

0.2811

F

4:

30

Then Do

03:

Z=F (P30)
1:

0

F

2:

0

Exponent of 10

3:

1*

Z Loc [ WndS_m_s ]

04:

End (P95)

05:

Excite-Delay (SE) (P4)
1:

1

Reps

2:

5**

± 2500 mV Slow Range

3:

5*

SE Channel

4:

3*

Excite all reps w/Exchan 3

5:

2

Delay (units 0.01 sec)

6:

2500**

mV Excitation

7:

2*

Loc [ WndD_deg ]

8:

0.288

Mult

9:

0

Offset

06:

If time is (P92)
1:

0

Minutes (Seconds --) into a

2:

30

Interval (same units as above)

3:

10

Set Output Flag High (Flag 0)

07:

Real Time (P77)
1:

0110

Day,Hour/Minute

08:

Wind Vector (P69)
1:

1

Reps

2:

0

Samples per Sub-Interval

3:

00

S,

θu, & σ(θu) Polar***

4:

1*

Wind Speed [ WndS_m_s ]

5:

2*

Wind Direction [ WndD_deg ]