6. Maintenance

The solar charge controller is maintenance-free.
All components of the PV system must be checked at least annually, according to the

specifications of the respective manufacturers.

Ensure adequate ventilation of the cooling element.
Check the cable strain relief.
Check that all cable connections are secure.
Tighten screws if necessary.
Terminal corrosion

7. Faults and remedies

Fault

Cause

Remedy

No display

battery voltage too low

pre-charge the battery

the external fuse in the

battery connection cable has

blown.

replace the external fuse

battery is not connected

unclamp all connections
connect a (new) battery with

the correct polarity
reconnect the solar module

and loads

1.
.

3.

battery is connected with the

wrong polarity

battery is defective

Info LED flashes

red

charging interrupted due to

excessive charging current

charging automatically con-

tinues as soon as the charging

current lies within the permis-

sible range

Load cannot be op-

erated or only for a

short time
+
info LED flashes

red

load output is switched off

due to excessive load current

reduce load current, if neces-

sary switch off or disconnect

loads
check loads

load output is switched off

due to short circuit at load

output

disconnect loads
correct the cause of the short

circuit
reconnect loads

1.
.

3.

load output is switched off

due to overheating of the

solar charge controller

the load output automatically

switches on again once the

solar charge controller has

cooled down

improve the cooling air

circulation
remove any other heat

sources
check the conditions of use

and the mounting location

Load cannot be

operated
+
info LED flashes

red
+
red battery LED

flashes

load output is switched

off due to too low battery

voltage

the load output automatically

switched on again as soon as

the battery voltage lies within

the permissible range

pre-charge the battery
equip loads directly con-

nected to the battery with

deep discharge protection
check the battery and replace

if necessary





7