2. electrical performance – Samlex America SK User Manual
Page 5

2-2. Electrical Performance
Specification
Model No.
Item
SK700-112 SK700-124 SK700-148 SK700-212 SK700-224 SK700-248
Continuous Output Power
700W
Maximum Output Power
770W
Surge Rating (Max.)
1400W
Input
voltage
12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V +/- 5%
220 / 230 / 240V +/- 3%
Frequency
(Switch Selections)
50 / 60Hz +/- 0.05%
Output Waveform
Pure Sine Wave ( THD < 3% )
Efficiency (full load) Max.
*1
89.0% 91.0% 92.0% 91.0% 93.0% 94.0%
No Load Current Draw (Max.)
1.25A
0.64A
0.31A
1.20A
0.60A
0.28A
Stand-By Current Draw (Max.)
0.25A
0.15A
0.08A
0.25A
0.15A
0.08A
Input Voltage Regulation
10.5-15
VDC
21.0-30
VDC
42-60
VDC
10.5-15
VDC
21.0-30
VDC
42-60
VDC
Input Level Indicator
Load Level Indicator
Red / Orange / Green LED
Failure Indicator
Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature.
Remote Control Unit
CR-6 / CR-7 / CR-8 Optional
Safety Cert.
Meet UL458
EN60950-1
EMC
FCC Class A
EN55022: 1997
EN55024: 1997
EN61000-3-2: 1998
EN61000-3-3: 1995
e-mark
e13 022986
Operating Temperature Range
0 - 40 ℃
Storage Temperature Range
-30℃ to 70℃
Cooling
Loading controlled cooling fan
Dimensions
295(L)*180(W)*72(H)mm / 11.61(L)*7.09(W)*2.83(H) Inch
Weight
2.7kg / 5.4 Lbs.
Note: The specifications are subject to change without notice.
3