3-2-3. DC Input Terminal:

Connect DC input terminal to 12V / 24V / 48V battery or the other
power sources.

【+】represents positive, and【-】represents negative. Reverse

polarity connection will blow the internal fuse and may damage the
inverter permanently.

DC Input Voltage

Model

Minimum

Maximum

12 V

10.5

15.0

24 V

21.0

30.0

48 V

42.0

60.0

3-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis.

3-3. Protections Features:

DC Input (VDC)

Over Temperature Protection

Over Voltage

Under

Voltage

INTERIOR

HEAT SINK

Model

Shut-

down

Restart

Under

Voltage

Alarm

Shut-

down

Restart

Shut-

down

Restart

Shut-

down

Restart

12

V 15.3 14.3 11.0 10.2 12.7

24

V 30.6 28.8 22.0 20.3 25.2

48V

61.0 58.1 44.0 40.8 49.7

70 45

90 60

WARNING!

Operating the inverter without a proper ground
Connection may cause an electrical hazard.