3-5-1. Connect the cables to the power input terminals on the rear panel of

the inverter. The red terminal is represents positive (+) and black
terminal represents negative (-). Insert the cables into the terminals
and tighten the screw to clamp the wires securely.

Also, use only high quality copper wire and keep cable length short, a

maximum of 3 - 6 feet.

WARNING!

The installation of a fuse must be on a positive cable.
Failure to place a fuse on “+” cables running between
the inverter and battery may cause damage to the
inverter and will void warranty.

WARNING!

Ensure all the DC connections are tight (torque
to 9 – 10 ft-lbs, 11.7 – 13 Nm). Loose connections
may cause overheat and fire.

AWG#2 - #6

Battery to inverter cable connection

Do not place anything between
battery cable lug and terminal surface.

Assemble exactly as shown.