2. electrical performance – Samlex America S1500 User Manual
Page 6

2-2. Electrical Performance
Specification
Model No.
Item S1500-112 S1500-124 S1500-148 S1500-212
S1500-224 S1500-248
Continuous Output Power
1500W
Surge Rating
2000W
Input Voltage
12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 115 / 120V +/- 5%
200 / 220 / 230 / 240V +/- 3%
Frequency
(Switch Selectable)
50 / 60Hz +/- 0.05%
Peak Output Current
25A 11A
Efficiency (full load)
85% 87% 88% 86% 89% 90%
No Load Current Draw
≦1.5W Saving Mode
Output Waveform
Sine Wave <3% THD
Output Voltage Regulation
100 / 110 / 115 / 120V RMS
-10% / +4%
200 / 220 / 230 / 240V RMS
-10% / +4%
Input Voltage Regulation
10-16
VDC
20-32
VDC
42-62
VDC
10-16
VDC
20-32
VDC
42-62
VDC
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under
Input Voltage, Over Temperature.
Power Saving Recovery
Time
5 Second
Interface Control Port
RS-232C With Baud Rate 1200,2400,4800 (Switch Selectable)
Remote Control Unit
CR-5 Optional
Safety
UL458 EN60950
EMC
FCC Class B
EN50081-1:1992
EN50082-1:1992
EN55022B:1994
EN61000-4-2:1995
EN61000-4-3:1996
ENV50204:1995
e-MARK
e13-020932
Operating Temperature Range
0 - 40℃
Storage Temperature Range
-30℃ to 70℃
Dimensions
390 (L) x 275 (W) x 105 (H) mm / 15.4 (L) x 10.8 (W) x 4.1 (H) Inch
Cooling
Thermostatically controlled cooling fan ( 55℃ ON , 45℃ OFF)
Weight
7.0kgs / 15.5 lbs.
3