beautypg.com

Samlex America S1500 User Manual

Page 12

background image

3-2-3. RS-232C:

Connect to remote control unit (option accessory) or taken remote
controlled working status by computer.

3-2-4. Connect chassis ground terminal to earth or to vehicle chassis using

#8 AWG wire.










3-3. Protection Feature

DC Input

Over voltage

Under Voltage

Over

Temperature

Protection

Model

Shut-

down

Restart

Under

Voltage

Alarm

Shut-

down

Restart

Shut-

down

Restart

S1500-112

S1500-212

17.1VDC 15.8VDC

10.2VDC

9.5VDC 12.4VDC

S1500-124

S1500-224

34.1VDC 31.5VDC

20.4VDC

19.3VDC 24.8VDC

S1500-148

S1500-248

63.0VDC 58.5VDC

41.6VDC

38.6VDC 49.6VDC

85

45

WARNING!

Operation of the inverter without a proper ground
connection may result in an electrical safety hazard.

9