background image

4. Troubleshooting guide

Problems and Symptoms

Possible Cause

Solutions

Low output voltage

Using average reading

voltmeter

Use true RMS reading meter
and cable.

See

page

15

Point

3-7-7.

of manual

Load LED bar flash.

Overload

Reduce load.

No output voltage.

Low input voltage.

Recharge battery,

And voltage indicator

check connections

in lower red zone.

and cable.

No output voltage.

Thermal shutdown

Improve ventilation,

Over Temp indicator

Make sure ventilation

on, load less than

openings in inverter

1500W.

are not obstructed.

Reduce

ambient

temperature.

No output voltage,

Short circuit or Wiring Check AC wiring

Over Load indicator

error.

for short circuit or

On. improper

polarity

(hot

and neutral reversed).

Very high power load

Remove load

WARNING!
Do not open or disassemble the Inverter.
Attempting to service the unit yourself may result in a risk of
electrical shock or fire.