beautypg.com

1000-0193_a4-18 – Samlex America SA-2000K User Manual

Page 18

background image

www.samlexpower.com

3-7. Inverter Operation

To operate the power inverter, use the ON / OFF switch on the Front panel to

turn the power on. Then the power inverter is ready to deliver AC power to

your loads. If several loads are to be used, turn them on separately after the

inverter is “ON” in order to prevent activation of Over Load Protection “OLP”

due to combined starting surge power.

3-7-1. Set the power switch to “ON” position and the buzzer will send out

“Beep” sounds at the moment. Then the inverter will make self-

diagnosis, and the LED’s indicators will change various colors. Finally

the buzzer will “Beep” again and the Input Level and Status LED

indicators will turn to “Green” color, then the inverter starts to work

successfully.

3-7-2. Set the power switch to the OFF position, then the inverter stops and

all the lights go Off.

3-7-3. Set the power inverter switch to ON position and turn the test load On.

The inverter should supply power to the load. If you plan to accurately

measure the true output r.m.s. voltage of the inverter, a meter such as

FLUKE 45 BECKMAN 4410 or TRIPLETT 4200 must be used.

16