beautypg.com

1000-0193_a4-12 – Samlex America SA-2000K User Manual

Page 12

background image

www.samlexpower.com

Connect DC input terminal to 12V / 24V battery or the other power

sources.

【+】

represents positive, and【-】represents negative. Reverse

polarity connection will blow the internal fuse and may damage the

inverter permanently.

Model

DC Input Voltage

Minimum

Maximum

12 V

10.5

15.0

24 V

21.0

30.0

3-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis.

Operating the inverter without a proper ground

Connection may cause an electrical hazard.

WARNING!

3-3. Protections Features

Model

DC Input (VDC)

Over Temperature Protection

Over Voltage

Under

Voltage

Alarm

Under

Voltage

INTERIOR

HEAT SINK

Shut-
down

Restart

Shut-
down

Restart

Shut-
down

Restart

Shut-
down

Restart

12 V

15.3V

14.3V

11.0V

10.2V

12.7V

70

45

90

60

24 V

30.6V

28.8V

22.0V

20.3V

25.2V

10