LBL Lighting MO Surf Elec Xfmr 60w 277v/12v LED User Manual
Important safety information
1
CAUTION - RISK OF FIRE
This product requires installation by a qualified
electrician. Before installing be sure to read all
instructions and TURN THE POWER TO THE
ELECTRICAL BOX OFF.
Installation Instructions for
60 & 100 Watt Electronic Single Power Feed Surface
Mount Transformers for LED Fixtures
1.5
TRANS-SFE61/100_
980MRLSFELEDFSMT
G
P
I
:
ENERAL
RODUCT NFORMATION
This instruction is for the following models:
60 Watt Electronic Single Power Feed Surface Mount
Transformer for LED Fixtures (TRANS-SFE61_)
100 Watt Electronic Single Direct Power Feed Surface Mount
Transformer for LED Fixtures (TRANS-SFE100_)
This product can mount to either a 4” square electrical box with a
round plaster ring or an octagon electrical box.
This product is ETL listed only when all the products used are
supplied by LBL Lighting, is suitable only for indoor dry locations
and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in
accordance with local electrical codes.
This product may be dimmed only with a low voltage electronic
dimmer. Using a dimmer not designed for low voltage electronic
applications may cause undesirable noise and potentially shorten
the life of the transformer.
This product is intended for use with LBL Lighting low voltage
lighting systems only.
Read all instructions thoroughly before beginning installation.
Important Safety Information
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.
Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.
Turn the electrical power off before modifying the lighting system in
any way.
The fixtures used with the system must be identified to be used
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.
To reset the electronic surface mount transformer, turn the power
off then on (main power, breaker panel, or wall switch).