Check the system, Save these instructions, 1a 2a – LBL Lighting MO Rmt Mag Xfmr 600w 120v/12v User Manual
Page 4

4
Check the System
After installing the entire low voltage system, if the
lamps have low intensity, then measure the voltage at
the fixture closest to the power feed contacts with a
voltmeter. The voltmeter should read between 11V - 12V
~AC. If the voltage does not fall in this range, call
Encompass Lighting Group "Technical Support" at 847-
410-4606.
After installing the entire system, operate the system for
five minutes. On the low voltage side, all electrical
connection points should be no more than warm to the
touch. If a connection is hot to the touch, re-tighten the
connection and check to ensure that the temperature
decreases.
The transformer circuit breaker will trip if there is a short
in the system. After removing the cause of the short, the
circuit breaker needs to be reset to power the system
up.
Replace the transformer cover and tighten the two
Phillips screws on the sides of the transformer.
COMX X1
X2
X3
X4 COMY Y1
Y2
Y3
Y4
10
11
12
13
PHILLIPS
SCREW
CIRCUIT BREAKER
CIRCUIT
BREAKER
SAVE THESE INSTRUCTIONS!
1
2
3
4
4
4
3
3
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.generation-brands.com
© 2014 Generation Brands.All rights reserved.The "Genereation Brands"
graphic is a registered trademark of Generation Brands. Generation Brands
reserves the right to change specifications for product improvements without
notification.
A Generation Brands Company
1A
2A