Install the remote transformer, Low voltage wire size table – LBL Lighting MO Rmt Mag Xfmr 300w 120v/12v User Manual
Page 2
2
COM
X1
X2
X3
X4
Install the Remote Transformer
NOTE:
In order to use small gage wires from the
transformer to the electrical box, it is recommended to
install the remote transformer near (if possible) the
electrical box. See "Low Voltage Wire Size Table"
below.
Mount the transformer to a solid surface using the
keyhole slot on the mounting bracket (hardware not
included).
Remove the transformer cover by loosening the two
Phillips screws on the side of the transformer.
TRANSFORMER
BRACKET
TRANSFORMER
BRACKET
PHILLIPS
SCREW
1
2
1
1
2
2
COM
X1
X2
X3
X4
7
Install a conduit and power line wires from the panel to
remote transformer.
connect the power line wires to the panel at this
time.
Connect the 120V black transformer wire to the hot
power line wire with a wire nut.
Connect the 120V white transformer wire to the neutral
power line wire with a wire nut.
Do not
Connect the ground wire to the green wire or stud
labeled “ground” in the console.
HOT POWER
LINE WIRE
NEUTRAL
POWER
LINE WIRE
3
4
5
6
3
CONDUIT
5
6
TRANSFORMER
WATTAGE
WIRE SIZE
FOR 5 FT
WIRE SIZE
FOR 6-15 FT
WIRE SIZE
FOR 16-20 FT
WIRE SIZE
FOR 21-40 FT
WIRE SIZE
FOR 40-60 FT
WIRE SIZE
FOR 61-90 FT
LOW VOLTAGE WIRE SIZE TABLE
300 WATT
#6 GA
#4 GA
#1 GA
#1/0 GA
#3/0 GA
#10 GA
1A
TRANSFORMER COVER
1B
4
7