Install the transformer, Connect the transformer to the monorail, 1a 1b – LBL Lighting MO Pass-Through Direct-Feed Surf Elec Xfmr 300w 120v/12v User Manual
Page 2

1A
2B
1A
2A
1A
1D
1A
1C
2
Place all wires and wire nut connections inside the
electrical box and mount the transformer to the
electrical box with provided #8-32 screws.
#8-32 SCREW
#8-32 SCREW
Unscrew and remove the bushing cap and the
tightening tool.
Place the MonoRail into the bushing.
Replace the bushing cap.
Screw the tool into the bushing cap.
Secure the MonoRail by using the tool to tighten the
bushing cap.
BUSHING CAP
TOOL
MONORAIL
BUSHING
Replace the tightening tool by screwing it back in
completely.
Reassemble the transformer by first aligning the tool
and the hole, then push up until it properly snaps back
into place.
TOOL
TOOL THREADS
TOOL
HOLE
Install the Transformer
THUMB RELEASE
BUTTON
THUMB RELEASE
BUTTON
Connect the Transformer to the MonoRail
Connect the mounting plate ground wire to a suitable
ground in accordance with local electrical codes.
Connect the white transformer wire to the neutral
power line wire with a wire nut.
Connect the black transformer wire to the hot power
line wire with a wire nut.
Press the thumb release buttons to separate the
transformer housing.
NOTE : The tightening tool must be screwed in
properly and completely in order for the bottom half
of the transformer to snap in correctly.
1A
1A
1A
1B
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.generation-brands.com
© 2013 Generation Brands.All rights reserved.The "Genereation Brands"
graphic is a registered trademark of Generation Brands. Generation Brands
reserves the right to change specifications for product improvements without
notification.
A Generation Brands Company
1
2
3
4
5
6
1
2
3
4
5
6
4
2
3
5
5
1
2
3