LBL Lighting Fusion Jack 4" Round Dome Flush Canopy w/Vault Adapter LED User Manual
Fusion jack, Use minimum 90°c supply conductors. 1a, Installation instructions for
Fusion Jack
™
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
1A
1
2
1
Installation Instructions for
Fusion Jack 4" Round Dome Canopy
for Vaulted Ceilings
1.1
CK001B-FJV-_
980FSJDMCV
G
P
I
:
ENERAL
RODUCT NFORMATION
This product is ETL listed and suitable only for dry locations and
approved for use at any height above the finished floor.
This product can be dimmed with a low-voltage electronic dimmer.
The mounting surface must not be greater than 40 degrees from
horizontal.
BACKPLATE
FLAT HEAD
SCREW
DOME
CANOPY
Loosen the two flat head screws to remove the backplate from
the dome canopy.
Connect the green transformer wire and backplate wire to a
suitable ground in accordance with local electrical codes.
Connect the white transformer wire to the neutral power line
wire with a wire nut.
Connect the black transformer wire to the hot power line
wire with a wire nut.
Place all wires and wire nut connections into the electrical box.
Mount the backplate to the electrical box with the two #8-32
round head screws.
Replace the dome cover onto the backplate. Replace and
tighten the two flat head screws.
POWER LINE WIRES
VAULTED
CEILING
ELECTRICAL
BOX
3
4
6
7
5
6
7
6
7
3
4
2