LBL Lighting Teardrop WCF User Manual
Tear drop (compact fluorescent), Install the fixture, Installation instructions for

Installation Instructions for
1.5
PW4601_SC13Q_
980TEARDWCF
G
P
I
:
ENERAL
RODUCT NFORMATION
This product can mount to either a 4" square electrical box with
round plaster ring or an octagon electrical box.
This product is suitable for damp locations.
Install the Fixture
Mount the crossbar assembly to the electrical box holes with
the two #8-32 screws provided.
CROSSBAR
ASSEMBLY
ELECTRICAL BOX HOLE
#8-32 SCREW
Feed the fixture wires through the mounting plate side hole.
Make sure that the crossbar is grounded in accordance with
local electrical codes.
Connect the fixture white wire to the neutral power line wire
with a wire nut.
Connect the fixture black wire to the hot power line wire with
a wire nut.
FIXTURE
WIRES
1
MOUNTING PLATE
Tear Drop (Compact Fluorescent)
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.