7 Appendix

7.1 Command Summary

Available commands below include identifying number, required parameters, the returned response and
an indication of whether settings are remembered always, never, or with remember set to on.

Table 23: Communication Command Summary

Name

Dec Hex ASCII Parameters Response

Remembered

Change Baud Rate

57

39

9

Byte

None

Always

Change I

2

C Slave Address

51

33

3

Byte

None

Always

Transmission Protocol Select

160

A0

á

Byte

None

Remember On

Set a Non-Standard Baud Rate 164

A4

ñ

Byte

None

Always

Table 24: Text Command Summary

Name

Dec Hex ASCII Parameters Response

Remembered

Clear Screen

88

58

X

None

None

Never

Change the Start Up Screen

64

40

@

Byte[]

None

Always

Auto Scroll On

81

51

Q

None

None

Remember On

Auto Scroll Off

82

52

R

None

None

Remember On

Set Auto Line Wrap On

67

43

C

None

None

Remember On

Set Auto Line Wrap Off

68

44

D

None

None

Remember On

Set Cursor Position

71

47

G

Byte[2]

None

Never

Go Home

72

48

H

None

None

Never

Move Cursor Back

76

4C

L

None

None

Never

Move Cursor Forward

77

4D

M

None

None

Never

Underline Cursor On

74

4A

J

None

None

Remember On

Underline Cursor Off

75

4B

K

None

None

Remember On

Blinking Block Cursor On

83

53

S

None

None

Remember On

Blinking Block Cursor Off

84

54

T

None

None

Remember On