6.9 Miscellaneous
9.1 Write
Customer Data
Dec
Hex
ASCII
254 52
FE 34
■ 4
Data
Data
Data
v5.6
Saves a user defined block of data to non-volatile memory. Useful for storing display information for later use.
Data
Byte [16]
User defined data.
9.2 Read
Customer Data
Dec
Hex
ASCII
254 53
FE 35
■ 5
v5.6
Reads data previously written to non-volatile memory. Data is only changed when written, surviving power cycles.
Response
Byte [16]
Previously saved user defined data.
9.3 Read Version
Number
Dec
Hex
ASCII
254 54
FE 36
■ 6
v5.6
Causes display to respond with its firmware version number. Test.
Response
Byte
Convert to hexadecimal to view major and minor revision numbers.
9.4 Read
Module Type
Dec
Hex
ASCII
254 55
FE 37
■ 7
v5.6
Causes display to respond with its module number.
Response
Byte
Module number, see Sample Module Type Responses for a partial list.
Table 22: Sample Module Type Responses
8
LK202-25
14
VK202-25
85
LK202-25-USB
86
VK202-25-USB