beautypg.com

7 data security – Matrix Orbital LK162A-4T User Manual

Page 26

background image

Command Summary

22

6.7 Set and Save
Contrast

Dec
Hex
ASCII

254 145

FE 91

■ æ

Contrast
Contrast
Contrast

v7.2

Immediately sets and saves the contrast between background and text. Although contrast can be changed using
the set command, it is reset to this saved value on start up. Default is 128.

Contrast

Byte

Contrast level from 0(Light) to 255(Dark).

6.7 Data Security

7.1 Set
Remember

Dec
Hex
ASCII

254 147

FE 93

■ ô

Switch
Switch
Switch

v7.2

Allows changes to specific settings to be saved to the display memory. Writing to non-volatile memory can be slow
and each change consumes 1 write of at least 100,000 available. The Command Summary outlines which
commands are saved always, never, and when this command is on only. Remember is off by default.

Switch

Byte

1 for on or 0 for off.

7.2 Set Data
Lock

Dec
Hex
ASCII

254 202 245 160

FE CA F5 A0

■ ╩ ⌡ á

Level
Level
Level

v7.2

Temporarily locks certain aspects of the display to ensure no inadvertent changes are made. The lock is released
after a power cycle. A new level overrides the old, and levels can be combined. Default is 0.

Level

Byte

Lock level, see Data Lock Bits table.

Table 14: Data Lock Bits

Display Command Reserved Setting Address Reserved Reserved Reserved

7

6

5

4

3

2

1

0

Table 15: Lock Parameters

Reserved

Place holders only, should be 0

Address

Locks the Baud Rate and I2C address

Setting

Locks all settings from being saved

Command

Locks all commands, text can still be written

Display

Locks entire display, no new text can be displayed

7.3 Set and Save
Data Lock

Dec
Hex
ASCII

254 203 245 160

FE CB F5 A0

■ ╦ ⌡ á

Level
Level
Level

v7.2

Locks certain aspects of the display to ensure no inadvertent changes are made. The lock is not affected by a
power cycle. A new level overrides the old, and levels can be combined. Default is 0.

Level

Byte

See Data Lock Bits table.