beautypg.com

4 general purpose output – Matrix Orbital LK162-12 User Manual

Page 23

background image

19

3.10 Initialize Wide
Vertical Bar

Dec
Hex
ASCII

254 118

FE 76

■ v

v5.1

Loads the wide horizontal bar graph custom character bank into memory. A wide bar is 5 pixels wide. Horizontal
bar characters must be initialized before a graph is displayed.


3.11 Place
Vertical Bar

Dec
Hex
ASCII

254 61

FE 3D

■ =

Column Length
Column Length
Column Length

v5.1

Places a vertical bar graph on the screen extending from the first row of the column specified. The bar extends
upwards to the length indicated. A new bar will over write the old.

Column

Byte

Value between 1 and 16.

Length

Byte

Height in pixels of the graph, value between 0 and 16.

7.4 General Purpose Output

4.1 General Purpose
Output On

Dec
Hex
ASCII

254 87

FE 57

■ W

Number
Number
Number

v5.1

Turns the specified GPO on, sourcing current from an output of five volts.

Number

Byte

GPO to be turned on.

4.2 General Purpose
Output Off

Dec
Hex
ASCII

254 86

FE 56

■ V

Number
Number
Number

v5.1

Turns the specified GPO off, sinking current to an output of zero volts.

Number

Byte

GPO to be turned off.


4.3 Set Start Up
GPO State

Dec
Hex
ASCII

254 195

FE C3

■ ├

Number State
Number State
Number State

v5.1

Sets and saves the start up state of the specified GPO in non volatile memory. Changes will be seen on start up.

Number

Byte

GPO to be controlled.

State

Byte

1 for on or 0 for off.


4.4 Set GPO
Mode

Dec
Hex
ASCII

254 37

FE 25

■ %

Mode
Mode
Mode

v5.1

Toggle the single GPIO header between general purpose output and keypad input.

Mode

Byte

General Purpose Output/Keypad Input Mode. 1 for GPO or 0 for keypad.