Cleanup - latex materials 2 – Wagner ProCoat Max User Manual
Page 17
English
17
5. Remove the inlet filter from
the suction tube and place
it into waste container.
6. Thread pump cleaning
adapter onto garden hose.
Thread suction tube fitting
over the adapter.
7. Unclip the return tube from the suction tube
and place it into the waste container.
Turn the PRIME/SPRAY knob to PRIME.
8. Turn the water supply to the garden hose on.
Turn the pump ON.
Water will go into the suction tube and out
through the return tube. Let the pump run
for a few minutes, and leave pump running
for next steps.
9. Point the spray gun at the side of
a waste container.
10. While squeezing the trigger, turn the
PRIME/SPRAY knob to SPRAY -
MINIMUM PRESSURE.
11. Continue squeezing the trigger
until fluid is coming out clear.
12. Perform Pressure Relief
Move on the Cleaning the Spray
gun Components, page 19.
5
6
7
8
9
PRIME
10
11
12
PRIME
l
O
ON