Cleanup (continued), Cleaning the nozzle, 2a 1 – Wagner Flexio 890 Sprayer User Manual
Page 13: 2b 4 5 3a, English, D) (e), Nozzle seal

English
© Wagner Spray Tech - All Rights Reserved
13
Cleanup (continued)
Cleaning the nozzle
To Clean the Nozzle:
1. Make sure power cord is unplugged. Remove the air
hose from the turbine.
2. iSpray nozzle only -
a. Remove the adjustment ring (a) carefully from the
connecting nut (b). Loosen the connecting nut.
b. Remove the parts as shown*. Clean all parts with a
cleaning brush and the appropriate cleaning solution.
To reassemble, see the instructions on the next page.
3. Detail Finish nozzle only -
a. Unscrew the nut and remove the air cap and nozzle.
Remove the parts as shown*. Clean all parts with a
cleaning brush and the appropriate cleaning solution.
Reassemble all parts when clean**.
4. Clean the air vent (c) on the suction tube with a soft
bristled cleaning brush.
5. Push the tab below the trigger, twist and separate the
nozzle from the handle.
Clean the rear of the nozzle (d) with the appropriate
cleaning solution. Use a thin layer of petroleum jelly to
lubricate the O-ring (e).
(a)
(b)
2a
1
(c)
(d)
(e)
2b
4
5
3a
* Nozzle seal
The red nozzle seal may become
stuck inside the spray nozzle
when the nozzle is removed. If
this occurs, make sure to pull
it out.
**
It is important that the nozzle
seal inside the nozzle be re-
installed properly. Make sure the
cup side of the seal (the side with
the groove) is facing out towards
the front of the nozzle. Improper
installation will cause leakage
Groove