beautypg.com

Section 2. installation, Mounting, No flange – MagTek INTELLISTRIPE 50 User Manual

Page 13: Small flange

background image

7

SECTION 2. INSTALLATION


The installation consists of

MOUNTING

No Flange

Shown in Section 1, Figure 1-3, the No Flange version is side mounted with four M3 (metric)
threaded inserts.

Small Flange

The small flange is shown in Section 1, Figure 1-2. The Small Flange version is front mounted,
and provides two holes of 3.30 mm (0.130”) diameter and two slots of 4.45 mm (0.180”) wide.
Various components of the IntelliStripe 50 Reader are shown in Figure 2-3 (below). The
orientation of the smartcard integrated circuit is with respect to the top view of the IntelliStripe
50 Reader.

PCB

10-Pin I/O
Connector

Flange Slot (2)

Flange Hole
Ø 3.30 mm (2 places)
Ø 0.130" (2 places)

Smartcard
Integrated
Circuit

ISO Contact Bracket

Bracket

Spring

Small Flange

Card Slot

10-Pin Connector
(8-Contact Smartcard Connector
1-Pin Card Seated Connector)

Gate Latch

Bracket

Flex Cable


Figure 2-1. Top View of IntelliStripe 50 Reader with Card