Key/value pairs for query the device, Able, Ection – MagTek Excella Windows API99875313 User Manual
Page 63: Evice, Sage, Apabilities

Section 4. Key-Value Pairs
55
KEY/VALUE PAIRS FOR QUERY THE DEVICE
The following sections are available upon query the device:
1. DeviceUsage
2. DeviceCapabilities
3. DeviceStatus
Table 4-20. Section = DeviceUsage
Key
Key Description
Value
Value Description
DocsRead
Number of Documents Read during the device
life span. If there is no RTC then this will be
same as ChecksRead.
Value
Number of documents
ChecksRead
Number of Documents Read since the last
power cycle.
Value
Number of documents
HoursOn
Number of hours on during the device life
span. If there is no RTC then this will be same
as HoursOp.
Value
Number of hours
HoursOp
Number of hours on since the last power cycle
Value
Number of hours
InkUsed
Number Ink drops expended.
Value
Number of ink drops
Table 4-21. Section = DeviceCapabilities
Key
Key Description
Value
Value Description
AutoFeed
The device can auto feed
a document.
T
T= TRUE
F
F=FALSE
Endorse
The device can endorse
the document.
BACK
Default
Firmware
This the firmware revision
String
Firmware version
Image
The device can scan the
image of front and back of
the document.
BOTH
The device scans both the front and the
back of the document.
FRONT
The device can only scan the front of the
document.
BACK
The device can only scan the back of
the document.
NONE
The device does not scan any image of
the document.
MICR
The device can read the
MICR data.
T
T= TRUE
F
F=FALSE
Stamp
The device does not have
a stamping capability at
this time.
NONE
Not available
UnitSerialNumber
This is the serial number
of the device.
NONE
Device serial number