Lyndex-Nikken Shrink Fit Machine Instructions User Manual
Page 4

ELCO
Shrink fit unit Start.2
27/04/2010
Page 4/19
1.2
Separate remote control
All controls are brought together on a separate remote control ; only the data
transmission wire links the box with the shrink fit unit.
The shrink fit unit can be used both by a right-handed user and a left-handed one, with
the same ergonomics.
On this remote control :
« Default » and « Control » lights (see §6.2 dysfunctionings) ;
in condition of normal use of the shrink fit unit, only the green
light should be on.
Selector (see §5.5): the « automatic » mode is activated by
default ;
By pushing the « MODE » button, the « manual » mode is
activated ;
By pushing again the « MODE » button, the « automatic »
mode is activated again.
Induction button : the induction works (yellow light) only if you press this
button ; if you stop pressing this button, the heating stops.
If you heat until the induction stops, the shrink fit unit will be blocked
and unusable for 30 seconds.
The cooling button : When you press this button, the cooling (if option)
begins. There is no need to keep pressing this button. During the cooling, the
green light is on.
After 2 minutes, the light flashes, then it is possible to stop the cooling by pressing
again this button.
After 15 minutes, if the operator has not stopped the cooling, it will stop automatically.
The second cooling button activates the second optional cooling unit ; its modus
operandi is identical to the one described previously and independent.