6.3
Maintenance
The only thing to be done by the user is a regular cleaning of the unit.
Fuses : The electronic card is equipped with fuses. If a fuse blows, you must determine
the reason. In any case, fuses must be replaced by others which have exactly the same
characteristics (3 fuses 10x38 690V-30A gRB Very high and fast cutoff power - FS-
A070gRB30T13-M330015).
If you do not respect this instruction, this could damage seriously the unit
Intervention :
In case of deterioration of the inductor, switch off the unit.
Before removing the electronic rack, switch off the unit.
Never open the unit without the manufacturer’s written authorization, and in any case,
before any intervention, the shrink fit unit must be disconnected from the electric
network.
Overall, any malfunction detected or any damaged part requires stopping the unit,
disconnecting it from the electric network, and needs to be reported to the
manufacturer’s after-sales service before re-operating the unit.
7 – TECHNICAL DATAS
Shrink fit unit :
Voltage
3 x 200 V / 240 V
50 Hz / 60 Hz
Power
14 kW
Dimensions
255 x 482 x 755 mm
Weight
20 kg