Note. After connecting the appliance check all fittings for gas leaks e.g. with soapy
water.
Do not check the fittings with open fire!
INSTALLATION
Notes for the technician
The fitter should:
•
Bear a valid certificate of gas permit
•
Have studied the contents of the appliance’s type plate containing the suitable
type of gas. Compare the data with the characteristics of the gas available in the
network.
•
Check the following:
- ventilation capacity, incl. air exchange in the kitchen,
- tightness and sealing of the gas fittings,
- effectiveness and correct operation of all the functional elements.
•
Adjust the settings of the gas control knobs with the washers included to ensure
the igniters work properly and the entire system is leak-proof;
- check the operation of the igniters and leak seal,
- remove the knob if working incorrectly, and adjust bi introducing washer(s) onto
the valve spindle,
- check the operation of the igniters and leak seal,
- secure the system with a tight washer and put the knob handle on.
•
Issue a certificate of connecting the appliance and inform the user of the operating
activities.
The cooktop is equipped with an R1/2” connecting pipe for gas connection. If the appliance
is intended for use with LPG (propane – butane), a Ø 8 x 1 mm hose coupling is threaded
onto the connector.
Make sure the gas connecting pipe does not come in contact with the metal components of
the cooktop.
All the couplings and joints must be tightly sealed.
NOTE!
Installation and service must be performed by a qualified and licensed instal-
ler, service agency or gas supplier. All the relevant safety regulations must be
observed.