2. Technical Data

a. Gas Specifications

Shaded areas are stated in metric equivalents

* Measured at the gas valve pressure tap when the gas valve is on.

b. Gas Connections:

Inlet connection --- 1-1/2” F.P.T.
Inlet supply size --- 1-1/2” Pipe Diameter (minimum)
Btu/hr input --------- 550,000 (138,598 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water
column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

The dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that
the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve
pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation
provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an
external regulator must be added to each dryer.

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas ................ #2

= 0.2210” (5.6134 mm).

Liquid Propane Gas .... #29 = 0.1360” (3.4544 mm).

TYPE OF GAS

Liquid

Propane

Conversion Kit

Part Number

Btu/hr

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty.

D.M.S.*

Part No.

Qty.

D.M.S.*

Part No.

550,000

138,598

4

#2

140839

4

#29

140820

880978

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb