Electrical oven component application chart – ADC AD-30V User Manual
Page 56
56
American Dryer Corporation
45034
3
-4
kW
Voltage
Phase
Wire
Oven
Assembly
y
Part No.
Element
Oven Wire
with Crimp Terminal
Terminal Lug
Bus Bar
Part No.
121011
Oven Relay
Qty.
kW
Part No.
Qty.
Size
Part No.
Qty.
Part No.
Cat. No.
Part No.
30
208
3Ø
3 or 4
883603
6
5
120012
1
#2
882562
1
121010
1
DPA93
131358
30
240
3Ø
3
824972
6
5
120013
1
#4
882566
1
121010
1
DPA73
131376
30
416
3Ø
3 or 4
826391
6
5
120013
1
#8
882571
2
121010
1
DPA43
131357
30
460/480
3Ø
3 or 4
824953
6
5
120013
1
#8
882572
1
121010
2
DPA43
131357
25
380
3Ø
3 or 4
826391
6
5
120013
1
#8
882571
1
121010
1
DPA43
131357
24
208
3Ø
3 or 4
883604
6
4
120010
1
#4
882566
1
121010
1
DPA73
131376
24
240
3Ø
3
883606
6
4
120011
1
#6
882568
1
121010
1
DPA63
131369
24
460/480
3Ø
3 or 4
883602
6
4
120011
1
#8
882572
1
121010
2
DPA33
131352
20
208
1Ø
2
883607
5
4
120010
1
#2
883384
1
121010
2
DPA93
131358
20
240
1Ø
2
883608
5
4
120011
1
#4
883385
1
121010
2
DPA93
131358
20
380
3Ø
3 or 4
883601
6
4
120010
1
#8
882571
1
121010
2
DPA33
131352
15
240
3Ø
3
883605
3
5
120013
1
#8
882571
1
121010
2
DPA43
131357
Electrical Oven Component
Application Chart