12.2 - Electrical components diagnosis
FAULT
PROBABLE CAUSE
REMEDY
13
THE GREEN PILOT LIGHT
“HL” DOES NOT LIGHT UP
Lamp burnt out.
Power supply
Short circuits
Main switch
Circuit breaker
Change it.
Check: - phases
- cables
- socket
- plug
Identify and eliminate.
Check the switch. In case of electrical
drop-out or overload cut-out, press switch
to start the machine again.
Reset the circuit breaker in case of
overload cout-out.
MOTOR STOPPED WITH PILOT
LIGHT “HL” LIT
Socket and plug connecting the
electric box/ microswitch in the handle
Microswitch “SQ 1” in the handle
Motor “M 1”
Check that the plug is correctly inserted
and look for any bad connections inside
the box.
Check operation and/or efficiency; replace
if broken.
Check that it is not burnt and that it turns
freely.
It may be rewound or changed.
NOISE TESTS
In accordance with point 1.7.4.f of the Machines Directive EEC 89/392
INTEGRATING PHONOMETER " DELTA OHM " mod. HD9019K1 serial n. 110996B295.
MICROPHONE mod. HD 9019S1.
SOUND GAUGER mod. HD 9101at 94dB/110dB a 1.000 Hz in class 1 according to IEC regulation n. 942 1988 and ANSI S1.40 1984.
3 measurements with the machine operating unloaded.
- The microphone was been located close to the operator's head, at medium height.
- The weighted equivalent continuous acoustic pressure level was 77,6 dB (A).
- The maximum level of the WEIGHTED instantaneous acoustic pressure C was always less than 130 dB.
NOTE: with the machine operating, the noise level will vary according to the different materials being processed. The user must
there-fore assess the intensity and if necessary provide the operators with the necessary personal protection, as required by Law
277/1991.