Aiwa HV-FX5100 User Manual
Page 15
![background image](/manuals/41001/15/background.png)
NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
Table 1
ADDRESS
DATA
ADDRESS
DATA
ADDRESS
DATA
ADDRESS
DATA
ADDRESS
DATA
CC
F1
D6
80
E0
76
EA
51
F4
41
CD
44
D7
00
E1
5E
EB
5F
83
F5
CE
24
D8
71
E2
08
EC
09
F6
3D
CF
88
D9
9F
E3
F0
ED
F0
F7
6B
D0
92
DA
02
E4
01
EE
05
0B
F8
D1
45
DB
0A
E5
F3
EF
F3
F9
0C
D2
00
DC
42
E6
6C
F0
00
FA
04
D3
02
DD
35
E7
2B
F1
2F
FB
3A
D4
09
DE
A3
E8
21
F2
DF
FC
99
D5
03
DF
56
E9
15
F3
41
3.
4.
5.
6.
7.
8.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS
DATA
1.
2.
Turn on the POWER and press both FF key and CH UP key on the set for more than 2 seconds.
ADDRESS and DATA should appear as FIG 1.
Fig. 1
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET + or - until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
C4-1