4.8.4 Log
Out
To log out of covert access mode, press and hold SET, then press “VCR VIEW”, then press
“PLAY”. Release the SET key.
4.9 Temporarily Disable Alarms
Alarms may be momentarily disabled by pressing and holding SET, then pressing the Camera 4
key.
Note that whenever SET is pressed again, the alarms will be re-enabled.
4.10 Quad and Multi Screen Video Interlace Selection
Press and hold SET, then press “Quad 1-4”, then press the quad or Multi-screen select keys (1-4, 5-
8, 9-12 etc.) to turn ON the lights of the Quads and Multi-screens that you wish to be interlaced.
4.11 User Defined Record Interval
Press and hold SET, then press “PLAY”, then press the camera select keys (1 or 2) to increase or
decrease the record interval (range 0.02 to 6.40 seconds).
Note the rotary switch must be in position F to take affect, although the user defined record interval
may be altered.
4.12 Factory-Set Defaults
Power off the multiplexer. While holding down the “SET”, “PLAY” and “AUTO FULL” keys
power on the multiplexer, wait for the confirmation of two beeps, release the keys. The dwell times
are all set to the minimum, all cameras are selected for sequencing and viewing (no covert cameras)
and the factory-set PIN number is “4321”.