Videoswitch VCM User Manual
Page 11

Duplex Multiplexers
User Manual
Page 11
____________________________________
Videoswitch
VCM614d.doc
3.5 Interface Connector Pin-out (25-way D-type)
All connections to the alarm inputs and outputs and the VCR step input are made via a 25-way D-
type connector on the rear panel of the multiplexer. A suitable mating connector (male) is provided.
This diagram shows the layout of the pins on the 25-way D-type (female) connector on the rear
panel:
Pin Function
1 Ground
2 Alarm
15
3 Alarm
17
4 Alarm
19
5
Alarm 9
6 Alarm
11
7 Alarm
13
8 Alarm
1
9 Alarm
3
10 Alarm
5
11 Alarm
7
12 Relay
N/O
13 Relay
N/C
14
Step Cable Input (connect to VCR “SW-OUT”)
15 Alarm
16
16 Alarm
18
17 Alarm
20
18 Alarm
10
19 Alarm
12
20 Alarm
14
21 Alarm
2
22 Alarm
4
23 Alarm
6
24 Alarm
8
25 Relay
Common
3.6 RS232 Connector Pin-out (3.5mm Jack)
The multiplexer may be controlled remotely via the RS232 connector (this facility is not currently
available on the 4 and 8 cameras models). A separate manual is available on request which gives
details the command set.