5 changing the installation position, 6 tightening torques, Assemble in reverse order (see 7.6) – ARI Armaturen CONA all-in-one PN40 EN User Manual
Page 14: Pos. 24) and tighten (see 7.6), Pos. 6) (see 7.6)
Page 14
Rev. 0040808000 0808
Operating and installation instructions
CONA
®
All-in-one
7.5 Changing the installation position
a) Ball float steam traps series 63A
(refer to Fig. 6 page 7)
-
Position body (pos. 1) as desired, bearing in mind the direction of flow
.
-
Remove hood (Pos 16), then slacken hollow-core screw (pos. 24.10) approximately
1/2 turn
.
- Rotate controller (pos. 24) 90° in the direction required.
-
Always fit controller (pos. 24) so that the ball float (pos. 24.16) can work in the vertical
plane
.
- Tighten hollow-core screw (pos. 24.10).
- Inspect and if necessary replace body seal (pos. 17).
- Put on hood (pos. 16) with drain plug (pos. 50) pointing down.
- Fit cheese head screws (pos. 27) (see 7.5) and tighten crosswise.
7.6 Tightening torques
(refer to Fig. 3 page 7 - Fig. 6 page 7)
Fig. 9: Controller series 63A, kpl.
pos.
Torque (Nm)
6
Screw cap
100
12
Threaded bush
10
13
Safety nut
70
14
Banjo bolt
70
15
Fitting
90
16
Stem guiding
90
24
Controller / seat
80