beautypg.com

0 troubleshooting, 0 troubleshooting table, Operating and installation instructions cona – ARI Armaturen CONA B PN630 EN User Manual

Page 13: B - bimetallic steam trap

background image

Rev. 0040803000 4610

Page 13

Operating and installation instructions

CONA

®

B - Bimetallic steam trap

8.0 Troubleshooting

In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.

If malfunctions cannot be eliminate with the help of the following table
9.0 Troubleshooting table”, the supplier or manufacturer should be consulted.

9.0 Troubleshooting table

-

ATTENTION !
- It is essential that the safety regulations are observed when identifying faults.

ATTENTION !
- refer to item 10.0 and 11.0 prio
r to dismantling and repair work!
- refer to item 6.0 befo
re restarting the plant !

Fault

Possible cause

Corrective measures

No flow

Installed in wrong flow direction

Fit valve in direction of flow arrow.
Note installation position

Flange covers not removed

Remove flange covers

Little flow

Strainer clogged (pos. 2)

Clean / replace strainer;
refer to item 7.1

Piping system clogged

Check piping system

Wrong controller size choosen

Correct selection acc. to flow diagram

Changed upstream pressure or back
pressure operating conditions

Correct selection acc. to flow diagram

No closure, or internal
leakage

Controller clogged

Clean strainer and controller;
refer to item 7.1

Controller worn out

Replace controller; refer to item 7.1

Controller misadjusted/incorrectly set

Change setting; refer to item 5.3

Controller incorrectly screwed into body Check seal face between body and con-

troller, tighten controller correctly ; refer
to item 7.3

Controller operated above safe operating
pressure

Observe operating limits as per data
sheet, i.e. possibly select a different con-
troller

External leakage

Screw cap (pos. 6) or cover with hex. nut
(pos. 28) not properly tightened

Tighten; refer to item 7.3

Seal (pos. 26) defective

Replace sealing; refer to item 7.3