Vaisala HMP140 User Manual
Page 18

HMP140A SERIES
Operating Manual
U175en-1.5
14
1999-12-08
6.4
Electromagnetic compatibility
6.4.1
Emissions
Test:
Setup according to:
Radiated interference
EN55022
(class B)
6.4.2
Interference
Test:
Setup according to: Performance:
Electrostatic discharge
IEC 801-2
criteria B
RF-radiated fields
IEC 801-3
criteria A
(allowed temporary effect
±
1
°
C in temperature)
Electrical fast transients
IEC 801-4
criteria B
7.
SPARE PARTS AND ACCESSORIES
Order code
Description
HMP233FA
mounting flange for the HMP143A
19326
junction box for the HMP143A cable extension
(seeApp.3)
1535
extension cable for the HMP143A (see Appendix 3)
17039HM
membrane filter
17038
plastic grid
HUMICAP
®
180
humidity sensor
GUARANTEE
Vaisala issues a guarantee for the material and workmanship of this product
under normal operating conditions for one (1) year from the date of delivery.