34. [RUP]

MT110-103 ONLY

This command ramps the output volume to its
maximum level at the rate defined using the
[RAMP] command.

Command Format: [RUPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on Output 1 from a
starting level of 10 to the maximum level of 32
for the card in slot 8. Send the commands
[SEL1C8] then [RUPC8] and the system will
respond with the following feedback:

[11][12][13][14]…[32]

35. [RDN]

MT110-103 ONLY

This command ramps the output volume down
to a level of 00 at a rate defined using the
[RAMP] command.

Command Format: [RDNCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on Output 1 from a
starting level of 32 down to 00 for the card in
slot 8. Send the commands [SEL1C8] then
[RDNC8] and the system will respond with the
following feedback:

[31][30][29]…[00]

36. [RUPm]

MT110-103 ONLY

This command ramps UP the output volume for
the specified output on the card. The ramping
will continue to its maximum level at the rate
defined using the [RAMP] command. The
ramping may be stopped at any time using the
[RST] command.

Command Format: [RUPmCnUi]

Cn = Card ID (n = # from 1 to max slots)

m

= Output No. (n = # from 1 to 8)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume for Output 2 from a
starting level of 10 to the maximum level of 32
for the card in slot 8. Send the command
[RUP2C8] and the system will respond with the
following feedback:

[11][12][13][14]…[32]

37. [RUPm=xx]

MT110-103 ONLY

This command ramps a specified output’s
volume to a user defined level at a rate defined
using the [RAMP] command.

Command Format: [RUPm=xxCnUi]

m

= Output No. (m = # from 1-8)

xx = Stop Level (xx = # from 01-32)

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on output 7 from a
starting level of 1 to a level of 20 for the card in
slot 8. Send the command [RUP7=20C8] and
the system will respond with the following
feedback:

[02][03][04]…[20]

38. [RDNm]

MT110-103 ONLY

This command ramps DOWN the output volume
for the specified output on the card. The
ramping will continue to its minimum level at the