beautypg.com

Haws 2500.FS User Manual

Page 6

background image

6/13

Model 2500.FS

Page 6 of 12

Step 9:

Press and hold the “Cold” button (see diagram under Operation section) until the ring around
the “Water” button turns blue. Press and hold the “Water” button until water begins to come
out of the nozzle (if it does not emit from the nozzle after a moment, consult the
Troubleshooting section).


Step 10:

Press and hold the “Hot” button (see diagram under Operation section) until the ring around
the “Water” button turns red. Press and hold the “Water” button. The hot tank will fill and
water will eventually begin to dispense. Stop and restart dispensing until all air is evidently
gone from the system

. Flip the hot tank power switch to “On.”

NOTE: Turning on the hot tank power without first filling the tank can damage the unit.


SIP Sanitization Setup

The cooler may be sanitized using the
integral SIP (Sanitize in Place) ozone
technology. This can be done by using
the default daily sanitization mode (see
below) or by running the SIP manually
for a more complete cleaning (see
Maintenance section).
NOTE: The system is not available
for use while the SIP sanitization is
running (approximately 1 hour), so it
is generally preferable to set it to run
when the unit is least likely to be
needed.


Step 11:

Press and hold the white button on the
back of the unit until it has beeped
twice (approximately 7 seconds). The
light

ring around the “Water” button will

begin flashing white.


Step 12:

The SIP system is designed to activate
automatically every 24 hours. Press
the white button

“X” number of times,

where

“X” equals the number of hours

from the current time until the desired
daily sanitization time, then press the
“Water” button to save the new setting.
Example: It is 2PM. You want the SIP to activate every day at 10PM, so you press the
white button 8 times, and then

press the “Water” button.

NOTE:

Pressing a button other than the “Water” button or the white SIP button, or waiting 15

seconds without pressing any button, will exit from setup mode without saving.

NOTE: Entering setup mode (as done in Step 11

) and immediately pressing the “Water”

button will turn the SIP functionality off.


Step 13:

Sanitize the exterior of the unit with Clorox

®

Anywhere

®

Hard Surface

TM

Daily Sanitizing

Spray before using.


See the Maintenance section for further instructions on the SIP user interface.