6. If relief valve appears to be limed-up, place it in a clean glass or

plastic container adequate in size so that you can pour enough

UN•LIME® into the container to cover the valve and allow space

for foaming. When foaming stops, run fresh cool water into the

container and rinse the relief valve for a few minutes.

7. If heater does not drain completely after a reasonable length

of time, turn off the main water supply valve to stop water from

entering the tank due to a by-pass problem or defective cold

water inlet valve. Also, check for clogged drain valve opening.

Heater must be completely drained before introducing UN•LIME.

8. Remove the cleanout cover and place a clean plastic bucket next

to the cleanout opening.
Partially open the cold water inlet valve to allow time to accomplish

the following and then close the valve.
While the water is being run through the tank, insert a stiff

wire, copper tube flattened at one end or an opened wire coat

hanger through the cleanout opening and scrape out any loose

deposits of scale or sediment. This is an economical way to avoid

unnecessary usage of the deliming solution.
Repeat the opening and closing of the cold water inlet valve as

necessary but be sure the heater is completely drained when

ready to introduce the UN•LIME.
Upon completion, reinstall the cleanout cover and use a new

cleanout cover gasket (part number 9004099215).
Remove the drain valve.

9. Install the long plastic male adapter insert fitting into the drain

valve opening of heater after applying Teflon tape or paste to

threads. Tighten firmly by hand and use wrench or adjustable

pliers to check for secure connection. Do not over tighten to avoid

damage to threads and fittings.

Prepare the Up-N-Down Transfer Kit
The next step is the preparation on the Up-N-Down Transfer Kit, if

you have not already done so:
1. With the 5 gallon Up-N-Down container in the vertical position,

unscrew plastic vent cap in the handle and pierce the plastic

membrane over the vent boss under cap to allow container to vent.
note: If your container does not have the vent cap and vent boss,

drill a 3/16” hole in the handle. When you have finished deliming

you will be able to plug this drilled vent with the stainless steel

screw that is supplied with the kit.

2. Remove the container’s cap and cut the plastic membrane

located in the 3/4” IPT opening in the cap. Take care to not

damage the threads.

3. Find the 3/4” male adapter, apply teflon tape to the threaded end

and screw it into the 3/4” IPT opening in the cap.

4. Put cap with male adapter back on the container and slide

3/4” hose over end of male adapter and fasten in place using

hose clamp provided.

Delime using Flo-Jug Method
5. Slide the hose clamp over end of hose and slide hose over the

male adapter in the water heater drain opening and secure in

place using hose clamp.

6. Lift container to the “Pour” Position, see Figure 29, being careful

to keep the vent in the handle above the liquid level and pour the

UN•LIME into the heater.

7. Lower container, you may have to place container on its empty

carton to prevent the UN•LIME from flowing back into container.

8. Let UN•LIME remain in the heater for 5 minutes and then lower

the container to the “Drain” Position, see Figure 29.

9. Deliming activity is indicated by foaming on the surface of the

UN•LIME. If there is deliming activity, repeat steps 6 thru 8.

Normally, lime removal will be completed within one hour. Severe

build-up of lime may take longer than an hour to complete descaling.
Note: To check UN•LIME for continued use, place some scale or

white chalk in a glass with a small amount of UN•LIME. If the material

is vigorously dissolved by the UN•LIME, it can be reused; if not, the

UN•LIME should be replaced.

fIGure 23.

draInInG and flushInG

It is recommended that the water heater storage tank be drained

and flushed every 6 months to reduce sediment buildup. The

water heater should be drained if being shut down during freezing

temperatures. See Features And Components in this manual for

the location of the water heater components described below.

Burn harzard.

Hot water discharge.

Keep hands clear of drain

valve discharge.

to draIn the water heater storaGe tanK:
1. Turn off the electrical supply to the water heater.
2. Turn off the gas supply at the Main Gas Shutoff Valve if the

water heater is going to be shut down for an extended period.

3. Ensure the cold water inlet valve is open.
4. Open a nearby hot water faucet and let the water run until the

water is no longer hot.

5. Close the cold water inlet valve to the water heater.
6. Connect a hose to the water heater drain valve and terminate

it to an adequate drain.

7. Open the water heater drain valve and allow all the water to

drain from the storage tank.

8. close the water heater drain valve when all water in the

storage tank has drained.

9. Close the hot water faucet opened in Step 4.
10. If the water heater is going to be shut down for an extended

period, the drain valve should be left open.

to flush the water heater storaGe tanK:
1. Turn off the electrical supply to the water heater.
2. Ensure the cold water inlet valve is open.
3. Open a nearby hot water faucet and let the water run until the

water is no longer hot. Then close the hot water faucet.

4. Connect a hose to drain valve and terminate it to an adequate drain.