beautypg.com

Periodic maintenance (cont’d), Drain valve washer replacement, Service – State P6 40 20T4 W User Manual

Page 18

background image

Periodic Maintenance (cont’d)

16. Replace terminal cover on thermostat and fold insula-

tion back over the element making sure that the lock-

ing tabs on the terminal cover are in place.

17. Fold the insulation back in place so that it completely

covers the thermostat and element.

18. Replace access panel.

19. Turn “ON” electric power to water heater.

Drain Valve Washer

Replacement

NOTE: For replacement, use a

17

32

" x

13

64

" x

1

8

" thick wash-

er available at your nearest hardware store.

1. Before beginning turn “OFF” the electrical power supply

to the water heater.

2. Follow “Draining” instructions. See “Draining” section.

3. Turning counter clockwise, remove the hex cap below

the screw handle.

4. Remove the washer and put the new one in place.

5. Screw the handle and cap assembly back into the drain

valve and retighten using a wrench. DO NOT OVER

TIGHTEN.

6. Follow “Filling the Water Heater” instructions in the

“Installing the New Water Heater” section.

7. Check for leaks.

8. Turn “ON” electric power to the water heater.

Service

If a condition persists or you are uncertain about the oper-

ation of the water heater, let a qualified person check it out.

Call a local plumbing contractor or qualified serviceman,

the local electric utility, or the local water utility.

18

WASHER

HANDLE AND
CAP ASSEMBLY

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater, make

sure the electrical supply to the water heater is turned

“off”. Failure to do this could result in DEATH, SERIOUS

BODILY INJURY, OR PROPERTY DAMAGE.