beautypg.com

Temperature regulation (cont’d), Temperature settings, Thermostat adjustment – State P6 40 20T4 W User Manual

Page 11: Thermostats

background image

Temperature Regulation (cont’d)

11

2. Take “OFF” the access panel and fold away the insula-

tion.

3. Turn the water temperature dial(s) clockwise (

) to

increase the temperature, or counter clockwise (

) to

decrease the temperature.

4. Fold the insulation back in place and replace the access

panel(s).

5. Turn “ON” the power supply.

Temperature Settings

HOT–Is a thermostat setting of approximately 120°F,

which will supply hot water at the most eco-

nomical temperatures.

A–Is a thermostat setting of approximately

130°F.

B–Is a thermostat setting of approximately

140°F.

C–Is a thermostat setting of approximately 150°F.

VERY HOT–Is a thermostat setting of approximately 160°F.

It is recommended that the dial be set lower

whenever possible.

NOTE: Water temperature range of 120˚-140˚ recom-

mended by most dishwasher manufacturers.

Thermostat Adjustment

On dual element models, both the upper and lower ther-

mostats have been factory set at HOT (approximately

120°F) to reduce the risk of scald injury.

The upper and lower thermostats are adjustable if a differ-

ent water temperature is desired. Read all warnings in the

“Temperature-Regulation” section before proceeding.

To adjust the temperature setting for both upper and lower

thermostats:

NOTE: It is not necessary to adjust the upper thermostat.

However, if it is adjusted above the factory set point

(120°F/HOT) it is recommended that it not be set higher

than the lower thermostat setting.

1. Turn “OFF” the electrical power to the water heater at

the junction box.

Thermostats

UPPER THERMOSTAT

(DUAL ELEMENT MODELS ONLY)

The lower thermostat is factory set at a position which

approximates 120°F (HOT) and is adjustable if a different

water temperature is desired. Read all warnings in this

manual and on the water heater before proceeding.

ADJUSTABLE LOWER

THERMOSTAT

(For dual element models)

ADJUSTABLE LOWER

THERMOSTAT

WITH HIGH LIMIT

The thermostat(s) of this water heater have been factory set

at a position which approximates 120°F (HOT) to reduce

the risk of scald injury.

The upper thermostat is factory set at a position which

approximates 120˚F(HOT) and is adjustable if a different

water temperature is desired. Read all warnings in this

manual and on the water heater before proceeding.

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater, make

sure the electrical supply to the water heater is turned

“off”. Failure to do this could result in DEATH, SERIOUS

BODILY INJURY, OR PROPERTY DAMAGE.