beautypg.com

Lighting instructions, For your safety read before lighting, Warning – State GS6 75 URRBS User Manual

Page 16

background image

16

FLAMMABLE

WARNING:

If you do not follow these instructions exactly, a

fire or explosion may result causing property damage, personal
injury or loss of life.

BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES

A.

C.

D.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.

Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire

department.

LIGHTING INSTRUCTIONS

TOP KNOB

FIGURE 'A'

"OFF" POSITION

OFF

ON

PILOT

FIGURE 'B'

"PILOT" POSITION

OFF

ON

PILOT

FIGURE 'C'

"ON" POSITION

OFF

ON

PILOT

1.

2.

TO TURN OFF GAS TO APPLIANCE

S e t t h e t h e r m o s t a t t o l o w e s t s e t t i n g .

Push gas control knob down slightly and turn clock-
wise to 'OFF'. Do not force. SEE FIGURE 'A'.

1.

10.

11.

12.

13.

2.

3.

5.

6.

7.

8.

9.

STOP! Read the safety information
above on this label.

Push the gas control knob down slightly and turn
clockwise to "OFF". SEE FIGURE 'A'.

NOTE: Knob cannot be turned from "PILOT" to "OFF"

unless knob is pushed down slightly. Do not force.

Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow "B" in the
safety information

above on this label. If

you do not smell gas,

go to next step.

This unit is equipped with a push button pilot ignitor,

on the gas control.

Continue to hold the gas control knob down for about
one (1) minute after the pilot is lit. Release the gas

control knob and it will pop back up. Pilot should

remain lit. If it goes out , repeat step (3) through (9).

It may take several minutes for air to clear the lines

before the pilot will light.
If knob does not pop up when released, stop and
immediately call your service technician or gas

supplier.
If the pilot will not stay lit after several tries,

turn the gas control knob clockwise to 'OFF' and

call your service technician or gas supplier.
SEE FIGURE 'A'

DANGER: Hotter water increases the risk

of scald injury. Consult the instruction
manual before changing temperature.

At arm's length away, turn gas control knob

counterclockwise to 'ON'. SEE FIGURE 'C'.
Set thermostat to desired setting.

Remove the outer door located below
the gas control unit.

4.

which is used to light the pilot. Locate the ignitor

Turn gas control knob counterclockwise

to "PILOT". SEE FIGURE 'B'.

Replace the outer door.

DIAL

PIL0T

KNOB

GAS CONTROL

RISK OF SCALDING

HOTTER WATER

INCREASES WITH

CAUTION:

THERMOSTAT

GAS CONTROL

PIEZO
IGNITOR
GENERATOR

The pilot is located on the left front corner of the burner.
It can be located by looking through the sight glass to
the left while pressing the piezo ignitor button
several times. Look for a spark at the pilot location .

Once the pilot has been found, push the gas knob
all the way down. Immediately press the pilot ignitor
button rapidly (4) to (5) times. If the pilot does not
light, repeat step (3) through (9).

This appliance has a pilot which is lit by a piezo-

electric spark gas ignition system. When lighting

the pilot, follow these instructions exactly.

B.

BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

Use only your hand to push down or turn the gas

control knob. Never use tools. If the knob will

not push down or turn by hand, don't try to repair

it, call a qualified service technician. Force or

attempted repair may result in fire or explosion.

Do not use this appliance if any part has been

under water. Immediately contact a qualified

installer or service agency to replace a flooded

water heater. Do not attempt to repair the unit!

It must be replaced!

Set the thermostat to the lowest setting by turning
thermostat dial fully clockwise until it stops.

FOR YOUR SAFETY READ BEFORE LIGHTING

FIGURE "D"

PILOT

MAIN BURNER

THERMOCOUPLE &

BURNER TUBE