beautypg.com

State GS6 40 YBFS User Manual

Page 26

background image

26

Removing the Burner from the Manifold/
Burner Assembly

Natural Gas (Low Nox) & L.P. Gas Burner

1. Take off the burner by removing the two (2) screws lo-

cated underneath the burner.

2. Check the burner to see if it is dirty or clogged. The burner

may be cleaned with soap and hot water (Figure 28).

BURNER

(BOTTOM VIEW)

SCREWS

FIGURE 28.

Replacing the Pilot/Igniter -
Flame Sensor Assembly

1. Remove the manifold assembly as directed previously.
2. Lift the retainer clip straight up from the back of

the manifold component block (using a flat-blade

screwdriver), then remove the manifold component

block from the manifold door (Figure 37).

3. Using a 7/16” wrench, loosen the nut securing the pilot

tube to the pilot assembly.
NOTE: To prevent any bending of the pilot bracket, use
pliers to hold the pilot assembly bracket while loosening
the pilot nut.

Pilot/Igniter-Flame Sensor Assembly

Manifold Component
Block

Pilot Tube

Igniter
Wire

Manifold Door

Retainer
Clip

FIGURE 29.

4. Pull the pilot tube from the pilot assembly (Figure

30).IMPORTANT: Be careful not to bend or alter the
position of the pilot assembly components.

5. Use a screwdriver to remove the screws securing the

Pilot/Igniter - Flame Sensor Assembly. Keep the screws
for reattachement.

6. Using the old pilot/pilot tube assembly as a guide, bend

the new pilot tube to match the old one. Make only the
bends closest to the pilot before going to the next step.

FIRST BEND(S)

OTHER FITTINGS
NOT SHOWN
FOR CLARITY

PILOT TUBE

SCREWS

OLD PILOT/IGNITER -
FLAME SENSOR ASSEMBLY

FIGURE 30.

7. Push the new pilot tube and igniter wire through the

hole in the manifold door (See Figure 31). Reconnect
the pilot tube and tighten the nut securing it to the pilot
assembly.
IMPORTANT: Keep the pilot orifice in the pilot when
making the connection. DO NOT operate the water
heater without the pilot orifice installed. Reattach the
pilot assembly to the manifold.

8. Be sure the igniter wire is positioned through the

bottom opening of the manifold component block. See
“Replacing Manifold Assembly” section.

MANIFOLD COMPONENT BLOCK

PILOT TUBE

IGNITER WIRE

FIGURE 31.

External Inspection & Cleaning of the
Base-Ring Filter

1. At least annually check the base-ring filter (Figure 32)

for any dust or debris that may have accumulated on the
filter screen. NOTE: If the water heater is located in an
area that is subjected to lint and dirt, it may be necessary
to check the base-ring filter more frequently.

2. Follow the Lighting Instructions to turn off the water

heater and allow it to cool for 10 minutes before
attempting to clean the base-ring filter.

3. Use a vacuum cleaner with a hose attachment to remove

any dust or debris that may have accumulated on the
filter. NOTE: If unable to inspect or clean the base-ring
filter, follow the “Cleaning the Combustion Chamber and
Flame-arrestor” instructions.

4. After the base-ring filter has been cleaned, follow the

Lighting Instructions to return the water heater to service.

This manual is related to the following products: